Floor and ceiling build-ups for separating floors over timber joists. Use the filter to narrow by performance or board.
| Reference | Build-up | Rw+Ctr (dB) | Rw (dB) | Lnw (dB) | Fire integrity (mins) | Fire insulation (mins) |
|---|---|---|---|---|---|---|
| C204003 | 21mm T&G wood flooring on Gyproc Plank 19mm on Gypframe SIF Floor Channel on timber joists 45 x 195mm solid joists at 450mm centres. Gypframe RB1 Resilient Bars fixed at 450mm centres lined with an inner layer of Gyproc Plank 19mm and an outer layer of Gyproc FireLine 12.5mm with 100mm Isover Spacesaver Ready-Cut in the cavity. | 51 | 63 | 55 | 60 | 60 |
| C204003 MR1 | 21mm T&G wood flooring on Gyproc Plank 19mm on Gypframe SIF Floor Channel on timber joists 45 x 195mm solid joists at 450mm centres. Gypframe RB1 Resilient Bars fixed at 450mm centres lined with an inner layer of Gyproc Plank 19mm and an outer layer of Gyproc FireLine MR 12.5mm with 100mm Isover Spacesaver Ready-Cut in the cavity. | 51 | 63 | 55 | 60 | 60 |
| C204006 | 21mm T&G wood flooring on Gyproc Plank 19mm on Gypframe SIF Floor Channel on timber joists 45 x 195mm solid joists at 450mm centres. Gypframe RB1 Resilient Bars fixed at 450mm centres lined with two layers of Gyproc SoundBloc 15mm with 100mm Isover Spacesaver Ready-Cut in the cavity. | 48 | 61 | 56 | 60 | 60 |
| C204006 MR1 | 21mm T&G wood flooring on Gyproc Plank 19mm on Gypframe SIF Floor Channel on timber joists 45 x 195mm solid joists at 450mm centres. Gypframe RB1 Resilient Bars fixed at 450mm centres lined with an inner layer of Gyproc SoundBloc 15mm and an outer layer of Gyproc SoundBloc MR 15mm with 100mm Isover Spacesaver Ready-Cut in the cavity. | 48 | 61 | 56 | 60 | 60 |
System references, build-ups and performance figures are British Gypsum's own data, reproduced here from British Gypsum White Book Specification Selector (EN systems) for reference only, with credit to British Gypsum.