ReferenceBuild-upFire protection (mins)Max section factor (m-1)Framed / frameless
D150001 (A)One layer of Gyproc FireLine 12.5mm providing 30 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 260 at a critical temperature of 550oC.30260Framed
D150001 (B)One layer of Gyproc FireLine 12.5mm providing 60 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 143 at a critical temperature of 550oC.60143Framed
D150001 (C)One layer of Gyproc FireLine 15mm providing 60 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 183 at a critical temperature of 550oC.60183Framed
D150001 (D)Two layers of Gyproc FireLine 12.5mm providing 60 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 260 at a critical temperature of 550oC.60260Framed
D150001 (E)One layer of Gyproc FireLine 12.5mm providing 90 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 63 at a critical temperature of 550oC.9063Framed
D150001 (F)One layer of Gyproc FireLine 15mm providing 90 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 72 at a critical temperature of 550oC.9072Framed
D150001 (G)Two layers of Gyproc FireLine 12.5mm providing 90 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 117 at a critical temperature of 550oC.90117Framed
D150001 (H)Two layers of Gyproc FireLine 15mm providing 90 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 260 at a critical temperature of 550oC.90260Framed
D150001 (I)Two layers of Gyproc FireLine 12.5mm providing 120 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 61 at a critical temperature of 550oC.12061Framed
D150001 (J)Two layers of Gyproc FireLine 15mm providing 120 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 88 at a critical temperature of 550oC.12088Framed
D150001 (K)Three layers of Gyproc FireLine 15mm providing 120 minutes fire protection to steel columns or beams up to a section factor A/V (HP/A) m-1 (max) of 260 at a critical temperature of 550oC.120260Framed

Source: British Gypsum White Book Specification Selector (EN systems), retrieved 9 October 2026. Figures as published by British Gypsum; each reference links to British Gypsum's own page for the full specification. Selected systems only - not the manufacturer's full range.