Wall linings fixed to steel CD sections, the fermacell adjustable wall liner or timber battens. The guide gives mass, thermal resistance and flanking sound only; no fire or height figures are published for these. Use the filter to narrow by performance or board.
| Reference | Build-up | Thickness (mm) | Mass (kg/m²) | Thermal resistance (m²K/W) | Flanking RL,w,R (dB) | |
|---|---|---|---|---|---|---|
| 3 WS 01 (CD 60 × 27) | 42.5–137.5 mm wall covering. CD 60 × 27 section (max. 600 mm centres unless stated); 12.5 mm fermacell fibre gypsum board to room side; mineral wool 20/20. | 42.5–137.5 | 17 | 0.53 | 57 | |
| 3 WS 01 (adjustable) | 42.5–162.5 mm wall covering. fermacell adjustable wall liner system (max. 600 mm centres unless stated); 12.5 mm fermacell fibre gypsum board to room side; mineral wool 50/20. | 42.5–162.5 | 20 | 1.28 | 57 | |
| 3 WS 02 (CD 60 × 27) | 55–143 mm wall covering. CD 60 × 27 section (max. 600 mm centres unless stated); 2 × 12.5 mm fermacell fibre gypsum board to room side; mineral wool 20/20. | 55–143 | 32 | 0.57 | 62 | |
| 3 WS 02 (adjustable) | 55–175 mm wall covering. fermacell adjustable wall liner system (max. 600 mm centres unless stated); 2 × 12.5 mm fermacell fibre gypsum board to room side; mineral wool 50/20. | 55–175 | 35 | 1.31 | 62 | |
| 3 WS 01 H₂O (CD 60 × 27) | 42.5–137.5 mm wall covering. CD 60 × 27 section (max. 600 mm centres unless stated); 12.5 mm Powerpanel H₂O to room side; mineral wool 20/20. | 42.5–137.5 | 14.5 | n/a | 57 | |
| 3 WS 01 H₂O (adjustable) | 42.5–162.5 mm wall covering. fermacell adjustable wall liner system (max. 600 mm centres unless stated); 12.5 mm Powerpanel H₂O to room side; mineral wool 50/20. | 42.5–162.5 | 17.5 | n/a | 57 | |
| 3 WS 02 H₂O (CD 60 × 27) | 55–150 mm wall covering. CD 60 × 27 section (max. 600 mm centres unless stated); 2 × 12.5 mm Powerpanel H₂O to room side; mineral wool 20/20. | 55–150 | 27 | n/a | 62 | |
| 3 WS 02 H₂O (adjustable) | 55–175 mm wall covering. fermacell adjustable wall liner system (max. 600 mm centres unless stated); 2 × 12.5 mm Powerpanel H₂O to room side; mineral wool 50/20. | 55–175 | 30 | n/a | 62 | |
| 3 WH 01 (37.5 mm) | 37.5 mm wall covering. 25/50 mm timber battens; 12.5 mm fermacell fibre gypsum board to room side; insulation optional. | 37.5 | 16 | 57 | ||
| 3 WH 01 (50.5 mm) | 50.5 mm wall covering. 38/50 mm timber battens; 12.5 mm fermacell fibre gypsum board to room side; insulation optional. | 50.5 | 16 | 57 | ||
| 3 WH 01 (62.5 mm) | 62.5 mm wall covering. 50/50 mm timber battens; 12.5 mm fermacell fibre gypsum board to room side; insulation optional. | 62.5 | 17 | 57 | ||
| 3 WH 02 (48.5 mm) | 48.5 mm wall covering. 25/50 mm timber battens; 12.5 + 10 mm fermacell fibre gypsum board to room side; insulation optional. | 48.5 | 32 | 61 | ||
| 3 WH 02 (60.5 mm) | 60.5 mm wall covering. 38/50 mm timber battens; 12.5 + 10 mm fermacell fibre gypsum board to room side; insulation optional. | 60.5 | 33 | 61 | ||
| 3 WH 02 (72.5 mm) | 72.5 mm wall covering. 50/50 mm timber battens; 12.5 + 10 mm fermacell fibre gypsum board to room side; insulation optional. | 72.5 | 34 | 61 |
System references, build-ups and performance figures are Fermacell's own data, reproduced here from fermacell Specification Guide for reference only, with credit to Fermacell.