Fermacell Steel beam and column encasement

8 system references

Technical Library › Fermacell › Steel beam and column encasement

We are a supply and fit installation contractor, not the manufacturer. Information here is reproduced from manufacturers' literature for reference only; always confirm it directly with the manufacturer before specifying, ordering or installing.

Firepanel A1 board encasement to steel universal beams (three-sided) and columns (four-sided) for R 30 to R 120 at a 550 °C critical temperature. fermacell gives no system codes here, so rows are named by element and rating. Use the filter to narrow by performance or board.

ReferenceBuild-upFire resistanceBoarding (mm)Section factor
Beam encasement R 30fermacell Firepanel A1 beam encasement, three-sided, minimum 12.5 mm boarding for UB/UC sections with Hp/A ≤ 300 m-1; critical steel temperature 550 °C (EN 13381-4, GA 2100/086/17 MPA BS). The guide's section factor charts give boarding for individual sections.R 3012.5Hp/A ≤ 300 m-1
Beam encasement R 60fermacell Firepanel A1 beam encasement, three-sided, minimum 12.5 + 15 mm boarding for UB/UC sections with Hp/A ≤ 300 m-1; critical steel temperature 550 °C (EN 13381-4, GA 2100/086/17 MPA BS). The guide's section factor charts give boarding for individual sections.R 6012.5 + 15Hp/A ≤ 300 m-1
Beam encasement R 90fermacell Firepanel A1 beam encasement, three-sided, minimum 3 × 12.5 mm boarding for UB/UC sections with Hp/A ≤ 300 m-1; critical steel temperature 550 °C (EN 13381-4, GA 2100/086/17 MPA BS). The guide's section factor charts give boarding for individual sections.R 903 × 12.5Hp/A ≤ 300 m-1
Beam encasement R 120fermacell Firepanel A1 beam encasement, three-sided, minimum 3 × 12.5 mm boarding for UB/UC sections with Hp/A ≤ 300 m-1; critical steel temperature 550 °C (EN 13381-4, GA 2100/086/17 MPA BS). The guide's section factor charts give boarding for individual sections.R 1203 × 12.5Hp/A ≤ 300 m-1
Column encasement R 30fermacell Firepanel A1 column encasement, four-sided, minimum 12.5 mm boarding for UB/UC sections with Hp/A ≤ 300 m-1; critical steel temperature 550 °C (EN 13381-4, GA 2100/086/17 MPA BS). The guide's section factor charts give boarding for individual sections.R 3012.5Hp/A ≤ 300 m-1
Column encasement R 60fermacell Firepanel A1 column encasement, four-sided, minimum 12.5 + 15 mm boarding for UB/UC sections with Hp/A ≤ 300 m-1; critical steel temperature 550 °C (EN 13381-4, GA 2100/086/17 MPA BS). The guide's section factor charts give boarding for individual sections.R 6012.5 + 15Hp/A ≤ 300 m-1
Column encasement R 90fermacell Firepanel A1 column encasement, four-sided, minimum 3 × 12.5 mm boarding for UB/UC sections with Hp/A ≤ 300 m-1; critical steel temperature 550 °C (EN 13381-4, GA 2100/086/17 MPA BS). The guide's section factor charts give boarding for individual sections.R 903 × 12.5Hp/A ≤ 300 m-1
Column encasement R 120fermacell Firepanel A1 column encasement, four-sided, minimum 3 × 12.5 mm boarding for UB/UC sections with Hp/A ≤ 300 m-1; critical steel temperature 550 °C (EN 13381-4, GA 2100/086/17 MPA BS). The guide's section factor charts give boarding for individual sections.R 1203 × 12.5Hp/A ≤ 300 m-1

System references, build-ups and performance figures are Fermacell's own data, reproduced here from fermacell Specification Guide for reference only, with credit to Fermacell.
Each reference links to Fermacell's page for the full, current specification - always specify from Fermacell's own documentation, HCI will not be held liable for a misspecification where this page has been used in lieu of the true manufacturer.
If you represent Fermacell and have a query pertaining to this library, please email info@howeceilings.co.uk. Data retrieved 10 October 2026.

Need one of these built?

Howe Ceilings & Interiors installs Fermacell systems across Glasgow, Edinburgh and the central belt. Send us the drawings and specification and we'll price it.

Talk to our team