Knauf Fireboard fleece-lined fire protection board

Knauf · Glass fleece-lined gypsum board for fire protection

Technical Library › Knauf › Knauf Fireboard

We are a supply and fit installation contractor, not the manufacturer. Information here is reproduced from manufacturers' literature for reference only; always confirm it directly with the manufacturer before specifying, ordering or installing.

About Knauf Fireboard

A fleece-faced gypsum board made for fire protection to structural steel and for Knauf smoke shaft systems. Supplied in 15 to 30mm thicknesses so the layer build-up can be matched to the required fire period.

Key performance

Compliance standardEN 15281:1:2008 + A1:2009
Thickness (mm)15, 20, 25, 30
Reaction to fire (R2F)A1
Thermal conductivity (λ)0.23
Plasterboard density (kg/m³)≥ 780
Areas of applicationTo be used as part of Knauf Frameless Fire Encasement and Smokeshaft systems.

Source: Knauf Fireboard product data sheet, revision reference 006, revision date 27/08/2026. Figures quoted exactly from the manufacturer's datasheet; confirm with Knauf before specifying.

Board data

Thickness (mm)Reaction to fire (R2F)Weight (kg/m²)Density (kg/m³)
15A112.8≥ 780
20A116.6≥ 780
25A120.7≥ 780
30A125.5≥ 780