Knauf Smokeshaft
2 system references
We are a supply and fit installation contractor, not the manufacturer. Information here is reproduced from manufacturers' literature for reference only; always confirm it directly with the manufacturer before specifying, ordering or installing.
Knauf smoke extraction shaft lining. Use the filter to narrow by performance or board. Search the reference in Knauf's System Finder for the full specification.
| Reference | Build-up | Fire resistance | Sound insulation | Max. height | Moisture protection | Thickness | |
|---|---|---|---|---|---|---|---|
| W172-60-6-0-001.uk | W172.uk. Width: 107 mm. Metal Studs 60 'I' (0.70) at 600 mm c/c.3x15 mm Fireboard (lobby/room side). 15mm Fireboard (shaft side). Height: 4000 mm. Fire resistance: 120 minutes. Sound reduction: 46dB(Rw) | EI 120 tested in accordance with EN 1364-1 | 46 dB | 4000 mm | none | 107 mm | |
| W172-60-6-0-002.uk | W172.uk. Width: 107 mm. Metal Studs 60 'I' (0.70) at 600 mm c/c.3x15 mm Fireboard (lobby/room side). 15mm Fireboard (shaft side). Height: 4000 mm. Fire resistance: 120 minutes. Sound reduction: 46dB(Rw) | EI 120 tested in accordance with EN 1364-1 | 46 dB | 4000 mm | none | 107 mm |
System references, build-ups and performance figures are Knauf's own data, reproduced here from Knauf System Finder (UK) for reference only, with credit to Knauf.
Each reference links to Knauf's page for the full, current specification - always specify from Knauf's own documentation, HCI will not be held liable for a misspecification where this page has been used in lieu of the true manufacturer.
If you represent Knauf and have a query pertaining to this library, please email info@howeceilings.co.uk. Data retrieved 10 October 2026.