Freestanding Siniat I stud wall linings, boarded on one side and clear of the existing wall, at 600mm or 400mm stud centres (400mm shown in brackets in the reference). Fire ratings are EN classified, from the boarded side only. Max height is the EN fire-state height for fire-rated systems and the cold-state height (L/240) where no fire rating is claimed. Use the filter to narrow by performance or board.

ReferenceBuild-upFire (mins)Max height (mm)Cold state height (mm)Thickness (mm)Weight (kg/m2)
IS50R-12St#01 x 12.5mm Siniat Standard Board on IS50/Rx at 600mm centres (I studs), freestanding lining, boarded one side; no insulation.2700270062.59.0
IS50R(400)-12St#01 x 12.5mm Siniat Standard Board on IS50/Rx at 400mm centres (I studs), freestanding lining, boarded one side; no insulation.3100310062.59.0
IS60B-12St#01 x 12.5mm Siniat Standard Board on IS60/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation.3500350072.59.0
IS60B(400)-12St#01 x 12.5mm Siniat Standard Board on IS60/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation.4000400072.510.0
IS70B-12St#01 x 12.5mm Siniat Standard Board on IS70/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation.4000400082.59.0
IS70B(400)-12St#01 x 12.5mm Siniat Standard Board on IS70/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation.4500450082.510.0
IS90B-12St#01 x 12.5mm Siniat Standard Board on IS90/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation.47004700102.510.0
IS90B(400)-12St#01 x 12.5mm Siniat Standard Board on IS90/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation.54005400102.510.0
IS50R-12St#0-25G1 x 12.5mm Siniat Standard Board on IS50/Rx at 600mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool.2700270062.59.0
IS50R(400)-12St#0-25G1 x 12.5mm Siniat Standard Board on IS50/Rx at 400mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool.3100310062.510.0
IS60B-12St#0-25G1 x 12.5mm Siniat Standard Board on IS60/B at 600mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool.3500350072.510.0
IS60B(400)-12St#0-25G1 x 12.5mm Siniat Standard Board on IS60/B at 400mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool.4000400072.510.0
IS70B-12St#0-25G1 x 12.5mm Siniat Standard Board on IS70/B at 600mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool.4000400082.510.0
IS70B(400)-12St#0-25G1 x 12.5mm Siniat Standard Board on IS70/B at 400mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool.4500450082.510.0
IS90B-12St#0-25G1 x 12.5mm Siniat Standard Board on IS90/B at 600mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool.47004700102.510.0
IS90B(400)-12St#0-25G1 x 12.5mm Siniat Standard Board on IS90/B at 400mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool.54005400102.511.0
IS50R-212dB#02 x 12.5mm Siniat dB Board on IS50/Rx at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30280028007523.0
IS50R(400)-212dB#02 x 12.5mm Siniat dB Board on IS50/Rx at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30320032007523.0
IS60B-212dB#02 x 12.5mm Siniat dB Board on IS60/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30360036008523.0
IS60B(400)-212dB#02 x 12.5mm Siniat dB Board on IS60/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30400041008524.0
IS70B-212dB#02 x 12.5mm Siniat dB Board on IS70/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30400040009523.0
IS70B(400)-212dB#02 x 12.5mm Siniat dB Board on IS70/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30400046009524.0
IS90B-212dB#02 x 12.5mm Siniat dB Board on IS90/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.304000480011524.0
IS90B(400)-212dB#02 x 12.5mm Siniat dB Board on IS90/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.304000550011524.0
IS50R-212dB#0-25G2 x 12.5mm Siniat dB Board on IS50/Rx at 600mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool. Fire resistance from the boarded side only.30280028007523.0
IS50R(400)-212dB#0-25G2 x 12.5mm Siniat dB Board on IS50/Rx at 400mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool. Fire resistance from the boarded side only.30320032007524.0
IS60B-212dB#0-25G2 x 12.5mm Siniat dB Board on IS60/B at 600mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool. Fire resistance from the boarded side only.30360036008524.0
IS60B(400)-212dB#0-25G2 x 12.5mm Siniat dB Board on IS60/B at 400mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool. Fire resistance from the boarded side only.30400041008524.0
IS70B-212dB#0-25G2 x 12.5mm Siniat dB Board on IS70/B at 600mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool. Fire resistance from the boarded side only.30400040009524.0
IS70B(400)-212dB#0-25G2 x 12.5mm Siniat dB Board on IS70/B at 400mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool. Fire resistance from the boarded side only.30400046009524.0
IS90B-212dB#0-25G2 x 12.5mm Siniat dB Board on IS90/B at 600mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool. Fire resistance from the boarded side only.304000480011524.0
IS90B(400)-212dB#0-25G2 x 12.5mm Siniat dB Board on IS90/B at 400mm centres (I studs), freestanding lining, boarded one side; 25mm glass mineral wool. Fire resistance from the boarded side only.304000550011525.0
IS50R-212F#02 x 12.5mm Siniat Fire Board on IS50/Rx at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30280028007521.0
IS50R(400)-212F#02 x 12.5mm Siniat Fire Board on IS50/Rx at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30320032007522.0
IS60B-212F#02 x 12.5mm Siniat Fire Board on IS60/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30360036008522.0
IS60B(400)-212F#02 x 12.5mm Siniat Fire Board on IS60/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30400041008522.0
IS70B-212F#02 x 12.5mm Siniat Fire Board on IS70/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30400040009522.0
IS70B(400)-212F#02 x 12.5mm Siniat Fire Board on IS70/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.30400046009522.0
IS90B-212F#02 x 12.5mm Siniat Fire Board on IS90/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.304000480011522.0
IS90B(400)-212F#02 x 12.5mm Siniat Fire Board on IS90/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.304000550011523.0
IS50R-312F#03 x 12.5mm Siniat Fire Board on IS50/Rx at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.602900290087.532.0
IS50R(400)-312F#03 x 12.5mm Siniat Fire Board on IS50/Rx at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.603300330087.532.0
IS60B-312F#03 x 12.5mm Siniat Fire Board on IS60/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.603600360097.532.0
IS60B(400)-312F#03 x 12.5mm Siniat Fire Board on IS60/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.604000410097.532.0
IS70B-312F#03 x 12.5mm Siniat Fire Board on IS70/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.6040004000107.532.0
IS70B(400)-312F#03 x 12.5mm Siniat Fire Board on IS70/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.6040004600107.533.0
IS90B-312F#03 x 12.5mm Siniat Fire Board on IS90/B at 600mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.6040004800127.532.0
IS90B(400)-312F#03 x 12.5mm Siniat Fire Board on IS90/B at 400mm centres (I studs), freestanding lining, boarded one side; no insulation. Fire resistance from the boarded side only.6040005500127.533.0

System references, build-ups and performance figures are Siniat's own data, reproduced here from Siniat Drywall Manual for reference only, with credit to Siniat.
Each reference links to Siniat's page for the full, current specification - always specify from Siniat's own documentation, HCI will not be held liable for a misspecification where this page has been used in lieu of the true manufacturer.
If you represent Siniat and have a query pertaining to this library, please email info@howeceilings.co.uk. Data retrieved 10 October 2026.

Need one of these built?

Howe Ceilings & Interiors installs Siniat systems across Glasgow, Edinburgh and the central belt. Send us the drawings and specification and we'll price it.

Talk to our team