Single-frame partitions on Siniat's Resilient Acoustic Stud for higher sound insulation without going to a twin frame. Max height is Siniat's EN fire-state height (the figure Siniat say to use unless otherwise specified); the cold-state (mechanical, L/240 at 200Pa) height is shown alongside. Use the filter to narrow by performance or board.
| Reference | Build-up | Fire (mins) | Rw (dB) | Max height (mm) | Cold state height (mm) | Thickness (mm) | Duty | Weight (kg/m2) | |
|---|---|---|---|---|---|---|---|---|---|
| RAS70P-215dB-50G | 15mm Siniat dB Board + 15mm Siniat dB Board each side (inner + outer), RAS70/P Siniat Resilient Acoustic Studs at 600mm centres, 50mm glass mineral wool. Rw+Ctr correction -8 dB. | 90 | 58 | 3900 | 3900 | 130 | Severe | 54 | |
| RAS90P-215dB-50G | 15mm Siniat dB Board + 15mm Siniat dB Board each side (inner + outer), RAS90/P Siniat Resilient Acoustic Studs at 600mm centres, 50mm glass mineral wool. Rw+Ctr correction -7 dB. | 90 | 59 | 4000 | 4200 | 150 | Severe | 54 | |
| RAS90P-215dB-100G | 15mm Siniat dB Board + 15mm Siniat dB Board each side (inner + outer), RAS90/P Siniat Resilient Acoustic Studs at 600mm centres, 100mm glass mineral wool. Rw+Ctr correction -7 dB. | 90 | 60 | 4000 | 4200 | 150 | Severe | 55 | |
| RAS70P-15Un15dB-50G | 15mm Siniat dB Board + 15mm Siniat Universal Board each side (inner + outer), RAS70P Siniat Resilient Acoustic Studs at 600mm centres, 50mm glass mineral wool. Rw+Ctr correction -8 dB. | 120 | 58 | 3900 | 3900 | 130 | Severe | 53 |
System references, build-ups and performance figures are Siniat's own data, reproduced here from Siniat Drywall Manual for reference only, with credit to Siniat.
Each reference links to Siniat's page for the full, current specification - always specify from Siniat's own documentation, HCI will not be held liable for a misspecification where this page has been used in lieu of the true manufacturer.
If you represent Siniat and have a query pertaining to this library, please email info@howeceilings.co.uk. Data retrieved 10 October 2026.
Need one of these built?
Howe Ceilings & Interiors installs Siniat systems across Glasgow, Edinburgh and the central belt. Send us the drawings and specification and we'll price it.
Talk to our team